Desulfurization Corrosion Resistant Stainless Steel Fan
US$400.00-3,000.00 | 1 Piece (MOQ) |
Shandong Huayu Metal Material Co., Ltd.
Shandong, China
Last Login Date:
Dec 12, 2023
Business Type:
Trading Company, Other
Product Description
Company Info
Basic Info.
Product Description
GY6-51 boiler-induced draft fan is suitable for the supply and induced draft fan system of 2t/ h~670t/ h steam boilers in thermal power plants, and can also meet the performance parameters of fluidized bed furnace high-pressure head. This series of fans can also be used for dust removal, Mine ventilation, and general ventilation systems.
The conveying medium of the blower is air, and the medium conveyed by the induced draft fan is flue gas or gas containing impurity particles. If the concentration of impurities is less than 200mg/ m², it can be used for more than four years. If the concentration of impurities is large, it can be used, but the service life is relatively short. The maximum operating temperature of the blower must not exceed 250°C.
Model No | G/Y6-51 8D~29.5D |
Product name | Centrifugal Fan |
Application Industries | Widely used in large and medium-size factories,steel, textile, chemical,kiln, power plants, steam boiler, air treatment equipment, hot air circulation, equipment, factory/building etc |
Rotating Speed | 1450~480rpm |
Power | 15~2000KW |
Material | Q235,Stainless steel ,other |
Total Pressure | 2745-10980Pa |
Airflow | 11000-667000M3/H |
Voltage | 380V/400V/415V/440V/450V/660V/1140V |
Frequency | 50Hz/60Hz |
Temperature Resistance | -30~600 Degrees |
Color | Blue/White/Grey/Yellow/Customized |
Package | Wooden Box/Steel frame |
Specification | Can provide according to customers requirements sizes |
Impeller Type | Backward/Forward/Radial Blade |
Efficiency(%) | Over 90% |
Exported to | All Countries |
Place of Origin | Shandong China |
Brand Name | Huayu |
Warranty | 18 Months |
After-Sales Service | Field Installation, Commissioning, and Training |
For the transportation of flammable and explosive gases, it is equipped with cast aluminum impellers and explosion-proof motors and can be made into explosion-proof fans.
For gas transmission greater than 80° and less than 250°, water-bearing housings can be used, made of ordinary steel plates, and stainless steel is recommended for gas transmission greater than 250°.
As the temperature of the boiler-induced fan increases, the pressure of the fan will change to a certain extent, and the power of the equipped motor will also change. Please consult the manufacturer for details.
Y6-51 boiler-induced draft fan is based on the principle of converting kinetic energy into potential energy, using the high-speed rotating impeller to accelerate the gas, then decelerate, change the flow direction, and convert kinetic energy into potential energy (pressure). In a single-stage centrifugal fan, the gas enters the impeller from the axial direction, changes to the radial direction when passing through the impeller, and then enters the diffuser. In a diffuser, the gas changes direction, and the cross-sectional area of the duct increases to decelerate the gas flow. This deceleration converts kinetic energy into pressure energy. Pressure changes mainly occur in the impeller, followed by the diffusion process. In a multi-stage centrifugal fan, a reflux device is used to direct the airflow to the next impeller, resulting in a higher pressure [1].
The principle of the Y6-51 boiler-induced draft fan is basically the same as that of the turbine compressor. It is because the gas flow rate is low and the pressure changes little. Generally, it is not necessary to consider the change of the gas-specific volume, that is, the gas is treated as an incompressible fluid.
Centrifugal fans can be made into two types right-handed and left-handed. Viewed from the side of the motor: the impeller rotates clockwise, known as a right-rotating fan; the impeller rotates counterclockwise, known as a left-rotating fan.
Y6-51 boiler-induced draft fan form
1) Blower fan and induced draft fan are made into single suction form. Machine number №8~29.5
2) Each fan can be made into two forms left rotation or right rotation.
3) The position of the air outlet of the fan is represented by the same outlet angle as the casing.
4) The transmission mode of the fan is D type (that is, the cantilever structure), and the motor and the fan are connected by elastic couplings, which are directly connected to the drive.
5) An example of the full name of the product is as follows:
G6-51№18D right 90 degrees
Y6-51№18D left 0 degrees
FAQ
1.Q: What parameters need to be provided when you design the industrial centrifugal fans?
A: Air flow rate(m3/h), Total pressure(Pa) or Static pressure(Pa), Inlet temperature(°C), Voltage and frequency on the working site.
2. Q:What is your delivery time?
A:15-35workdays, depending on the model of the fan.
3.Q:What's your MOQ?
A:The MOQ is 1set,but larger quantity, lower price.
4.Q: What's your warranty?
A: 12 months after arrival of the goods on site.
5.Q:How do you control the product's quality?
A:All the products have quality testing and dynamic balance before delivery.